← Lab equipment

High-voltage pulse generator

Single or dual high-voltage pulse generators, chosen for high peak power and fine pulse control: what it takes to fault modern ICs without crossing into permanent damage.

Capabilities

What it does

Pulse Generator
Pulse Generator 2
High peak power

Up to 3000 V peak voltage at 50 Ω load.

Fine control at the fault boundary

500 ps rise time and delay steps down to 100 ps, to find the exact threshold where faults start without damaging the target.

Dual-pulse option

A second, independently delayed pulse (1 ns to 1 µs after the first), for attacks that need two coordinated faults.

Protected integration

Matched cables and an attenuator, so connecting the generator to the rest of your bench, like your oscilloscope, doesn’t risk damaging it.

Built-in triggering

Internal and external triggers, single-pulse command and finely tunable delay, plus a complementary delay generator to cover more situations.

Under the hood

Technical specifications

Peak voltageUp to 3000 V at 50 Ω
Rise time500 ps
Delay stepsDown to 100 ps
Second pulse (dual version)1 ns to 1 µs after the first
TriggersInternal, external, single-pulse command
Delivered withMatched cables, attenuator
Turnkey labs

Get the full setup for your attack

Everything your team needs to run this attack, from the software to the complete hardware lab, delivered and installed on your site.